XB01VG series swash plate type axial piston variable displacement pump is used in the closed circuit of hydrostatic transmission. The flow rate is proportional to the driving speed and displacement and can be infinitely variable. Various variable control methods can be selected, such as manual, hydraulic control, and electric ratio Control, etc. Multiple hydraulic control valves can be integrated to avoid overload. Different control methods can be configured according to customer needs. The degree of automation is high. Remote control operations can be realized. The through-shaft design is used to meet the various needs of the hydraulic system. Can replace imported Rexroth A4VG series axial piston pump.

 

 

 

 

 

 

Model

Instruction

 

 

 

 

 

 

XB01VG 

 

 

125

 

 

HD3

 

 

D

 

 

2

 

 

R

 

 

N

 

 

F

 

 

P

 

 

 

 

Axial

  plunger element

 

 

Component displacement

 

 

control method 

 

 

With switch electromagnet

 

 

DA control valve

 

 

turn around

 

 

Sealing method

 

 

Charge pump

 

 

Filter type

 

 

 

 

Swashplate Closed Variable Axial

  Piston Pump

 

 

71

 

 

HD3: Hydraulic control (related

  to pilot pressure), with oil supply filter

 

 

D: With pressure cut-off valve (standard)

 

 

1: No DA control valve

 

 

R: clockwise

 

 

N: NBR (nitrile rubber)

 

 

With built-in

 

 

Filter in the pressure line of the charge pump;

  the filter is equipped with a cold start valve and a pollution indicator in

  the form of a right side; window type

 

 

 

 

  

 

 

HW: Mechanical servo hydraulic

  control

 

 

2: With DA control valve, fixed

  set value

 

 

  

 

 

Shaft seal FKM (fluoro rubber)

 

 

Charge pump

 

 

 

 

125

 

 

 

 

 

 

 

 

L: counterclockwise

 

 

 

 

 

 

 

 

 

 

 

 

Technical Feature

 

 

 

 

 

 

Axial piston variable displacement pump with swash plate structure for hydrostatic transmission in closed circuit

 

 

 

 

The flow is proportional to the driving speed and displacement and can be adjusted steplessly

 

 

 

 

Output flow increases from zero to maximum with swashplate swing angle

 

 

 

 

A variety of highly compatible control equipment, providing various control and adjustment functions

 

 

 

 

Each high pressure side is equipped with two relief valves to prevent the hydrostatic transmission (pump and motor) from overloading

 

 

 

 

Relief valve also has charge valve function, built-in pressure shut-off valve is standard

 

 

 

 

Built-in charge pump is used as fuel supply and control pump. The maximum charge pressure is limited by the built-in charge relief valve.

 

 

 

Specification

 

 

 

 

 

 

Specifications / technical data

 

 

Displacement

 

 

charge pump

 

 

speed

 

 

Rated speed

 

 

minimum value

 

 

Rated torque  

 

 

power

 

 

Weight 

 

 

 

 

mL/r   

 

 

mL/r   

 

 

rpm   

 

 

rpm   

 

 

rpm   

 

 

N·m  

 

 

kW  

 

 

kg   

 

 

 

 

71   

 

 

71   

 

 

19.6   

 

 

3300   

 

 

3300   

 

 

500   

 

 

451   

 

 

156   

 

 

50   

 

 

 

 

125   

 

 

125   

 

 

28.3   

 

 

2850   

 

 

2850   

 

 

500   

 

 

765   

 

 

273   

 

 

80   

 

 

 

 

 

 