Multi-jet Liquid-Sealed Water Meter

0 votes
asked Dec 8, 2022 in 3D Segmentation by netcec001 (677,960 points)
Multi Jet 15mm Class C Water

Meter is produced in the versions for

cold water (50℃)and hot

water (90℃) where flow is in one

direction for residential applications include the diameters 15mm to

40mm. This class C water meter is a new type of high precision water

meter. DN15mm water meter is the best seller.

 

 

Features:

 

 

Multi jet, Dry dial

Material body: Brass.

 

 

Sizes: DN15mm to DN40mm, (1/2” – 11/2”),

Available for cold water (50°C), hot water(90°C)

 

 

Accuracy: Class B / Class C / R160

 

 

Universal use. Easy for interchange &

maintenance

 

 

 

 

 

Working Conditions:

 

 

Water temperature:≤50℃ for cold water meter

 

 

Water temperature:≤90℃ for hot water meter

 

 

Working pressure:≤1.6Mpa

 

 

 

 

 

Main Technical Data:

 

 

 

 

 

 

 

 

 

Size

 

 

 

 

Class

 

 

 

 

Qs

Overload flow

 

 

 

 

Qp

Nominal flow

 

 

 

 

Qt

Transitional flow

 

 

 

 

Qmin

Min flow

 

 

 

 

Min reading

 

 

 

 

Max reading

 

 

 

 

 

 

DN(mm)

 

 

 

 

lnch

 

 

 

 

M3

 

 

 

 

L/h

 

 

 

 

M3

 

 

 

 

 

 

15

 

 

 

 

1/2"

 

 

 

 

A

 

 

 

 

3

 

 

 

 

1.5

 

 

 

 

150

 

 

 

 

60

 

 

 

 

0.0001

 

 

 

 

9999

 

 

 

 

 

 

B

 

 

 

 

120

 

 

 

 

30

 

 

 

 

 

 

c

 

 

 

 

22.5

 

 

 

 

15

 

 

 

 

 

 

20

 

 

 

 

¾”

 

 

 

 

A

 

 

 

 

5

 

 

 

 

2.5

 

 

 

 

250

 

 

 

 

100

 

 

 

 

0.0001

 

 

 

 

9999

 

 

 

 

 

 

B

 

 

 

 

200

 

 

 

 

50

 

 

 

 

 

 

c

 

 

 

 

37.5

 

 

 

 

25

 

 

 

 

 

 

25

 

 

 

 

1”

 

 

 

 

A

 

 

 

 

7

 

 

 

 

3.5

 

 

 

 

350

 

 

 

 

140

 

 

 

 

0.0001

 

 

 

 

9999

 

 

 

 

 

 

B

 

 

 

 

280

 

 

 

 

70

 

 

 

 

 

 

c

 

 

 

 

52.5

 

 

 

 

35

 

 

 

 

 

 

32

 

 

 

 

11/4”

 

 

 

 

A

 

 

 

 

12

 

 

 

 

6

 

 

 

 

600

 

 

 

 

240

 

 

 

 

0.0001

 

 

 

 

9999

 

 

 

 

 

 

B

 

 

 

 

480

 

 

 

 

120

 

 

 

 

 

 

c

 

 

 

 

9o

 

 

 

 

60

 

 

 

 

 

 

40

 

 

 

 

11/2”

 

 

 

 

A

 

 

 

 

20

 

 

 

 

10

 

 

 

 

1000

 

 

 

 

400

 

 

 

 

0.001

 

 

 

 

9999

 

 

 

 

 

 

B

 

 

 

 

80o

 

 

 

 

200

 

 

 

 

 

 

c

 

 

 

 

150

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN

SIZE

 

 

 

 

Mm

lnch

 

 

 

 

15

1/2"

 

 

 

 

20

3/4"

 

 

 

 

25

1"

 

 

 

 

32

11/4"

 

 

 

 

40

11/2"

 

 

 

 

 

 

Q4(M3/h)

 

 

 

 

3.125

 

 

 

 

5

 

 

 

 

7.875

 

 

 

 

12.5

 

 

 

 

20

 

 

 

 

 

 

Q3(M3/h)

 

 

 

 

2.5

 

 

 

 

4

 

 

 

 

6.3

 

 

 

 

10

 

 

 

 

16

 

 

 

 

 

 

R80

 

 

 

 

Q2(L/h)

 

 

 

 

50

 

 

 

 

80

 

 

 

 

126

 

 

 

 

200

 

 

 

 

320

 

 

 

 

 

 

Q1(L/h)

 

 

 

 

31.25

 

 

 

 

50

 

 

 

 

78.75

 

 

 

 

125

 

 

 

 

200

 

 

 

 

 

 

R100

 

 

 

 

Q2(L/h)

 

 

 

 

40

 

 

 

 

64

 

 

 

 

100.8

 

 

 

 

160

 

 

 

 

256

 

 

 

 

 

 

Q1(L/h)

 

 

 

 

25

 

 

 

 

40

 

 

 

 

63

 

 

 

 

100

 

 

 

 

160

 

 

 

 

 

 

R125

 

 

 

 

Q2(L/h)

 

 

 

 

32

 

 

 

 

51.2

 

 

 

 

80.64

 

 

 

 

128

 

 

 

 

204.8

 

 

 

 

 

 

Q1(L/h)

 

 

 

 

20

 

 

 

 

32

 

 

 

 

50.4

 

 

 

 

80

 

 

 

 

128

 

 

 

 

 

 

R160

 

 

 

 

Q2(L/h)

 

 

 

 

25

 

 

 

 

40

 

 

 

 

63

 

 

 

 

100

 

 

 

 

160

 

 

 

 

 

 

Q1(L/h)

 

 

 

 

15.625

 

 

 

 

25

 

 

 

 

39.375

 

 

 

 

62.5

 

 

 

 

100

 

 

 

 

 

 

Min reading(M3)

 

 

 

 

0.0001

 

 

 

 

0.0001

 

 

 

 

0.0001

 

 

 

 

0.0001

 

 

 

 

0.001

 

 

 

 

 

 

Max reading(M3)

 

 

 

 

9999

 

 

 

 

9999

 

 

 

 

9999

 

 

 

 

9999

 

 

 

 

9999

 

 

 

 

 

 

Max pressure(MAP)

 

 

 

 

16

 

 

 

 

16

 

 

 

 

16

 

 

 

 

16

 

 

 

 

16

 

 

 

 

 

 

Max loss(△P)

 

 

 

 

63

 

 

 

 

63

 

 

 

 

63

 

 

 

 

63

 

 

 

 

63

 

 

 

 

 

 

Max temperature

 

 

 

 

T50

 

 

 

 

T50

 

 

 

 

T50

 

 

 

 

T50

 

 

 

 

T50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDICATING ERROR

 

 

At low zone is ±5% from minimum flow rate (qmin) 

to transitional flow rate (qt) exclusive boundary

 

 

At high zone is ±2% from transitional flow

rate (qt) to overload flow rate (qs)

 

  https://www.chenshuometer.com/multi-jet-dry-dial-residential-water-meter/